Home Improvement6 min read

How Many Watts Does a Pellet Stove Use? Igniter, Running Watts and Outages

By Seamless Home Team, Home services operations · November 25, 2026 · Updated November 25, 2026

Quick answer

Less than most electric heaters, but more than people expect for a stove that burns wood. Two owner's manuals give a realistic picture: the Breckwell SP8000 lists about 175 W while operating and about 425 W while its igniter is running, and the Castle HPS09 lists 200 W operating and 520 W during ignition. The igniter only runs during startup — Breckwell says the fuel should light within 5 to 10 minutes — so most of the time the stove draws its operating figure for the auger, combustion fan and room blower. At 200 W, that is about 4.8 kWh over a full day. Without power, a pellet stove stops: both manuals say it will not operate during an outage.

A pellet stove burns compressed wood pellets, but it is an electrical appliance as much as a stove. A motor-driven auger feeds pellets from the hopper into the burn pot, an electric igniter lights them, a combustion fan pulls exhaust out through the vent, and a room blower pushes heat into the house. A control board runs all of it.

So "how many watts" has two answers: what the stove draws during startup, while the igniter is hot, and what it draws while running. Manufacturers list both in the owner's manual. Here is what they look like for two real stoves, and how to find yours.

What you wantWhere to find itWhat it tells you
Operating wattsmanual, "Specifications"Typical draw once the fire is lit
Ignition wattsmanual, "Specifications"Highest draw, during startup
Volts and ampsmanual or rating labelCircuit and outlet requirements
Real energy usea plug-in power meter or circuit monitorWhat it actually costs you

What two owner's manuals say

StoveOperatingIgnitionElectrical rating
Breckwell SP8000about 175 Wabout 425 W (igniter running)110–120 V, 60 Hz, 3.0 A
Castle HPS09200 W520 W110–120 V, 60 Hz, 4.5 A

The pattern is the useful part. Running draw sits around 175 to 200 watts — roughly double a box fan on high and far below a space heater — and startup roughly doubles or more while the igniter works. Other brands and larger stoves will differ, so read your own manual or rating label rather than relying on these two.

Why startup draws more

The igniter is a small electric heating element. It glows hot enough to light pellets in the burn pot, then shuts off once the fire is established. Breckwell's manual says the automatic ignition should light the fuel within 5 to 10 minutes of pressing ON. During that window the stove draws its ignition figure; afterwards it drops to the operating figure.

That matters in two places. Your circuit needs to carry the higher number, which both stoves do easily at 3 to 4.5 amps on a 120-volt outlet. And if you run the stove on battery or backup power, the inverter has to handle the startup draw, not just the running one. Our watts to amps calculator converts between the two.

Daily electricity use

To turn watts into energy: watts × hours ÷ 1,000 = kWh.

  • 200 W for 24 hours = 4.8 kWh
  • 175 W for 24 hours = 4.2 kWh
  • 200 W for 8 hours = 1.6 kWh
  • One startup at 520 W for 10 minutes ≈ 0.09 kWh

The operating figure in a manual is a specification, not a meter reading. Actual draw can vary with the heat setting and blower speed, so a plug-in power meter gives you the real number for your stove. The watts to kWh calculator does the arithmetic, and multiplying kWh by your electric rate gives the cost.

What happens in a power outage

This is the part buyers often miss. Without electricity, the auger stops feeding pellets and the fans stop. Breckwell's manual is blunt: the heater will not operate during a power outage. Castle's says the stove shuts down safely, the exhaust fan will not run, and — notably — the stove should not be used as the only source of heat in the house, because power outages will result in a total loss of heat.

The manuals also tell you what to do in the moment. Castle says to keep the main door and ash door closed so the vent can draft out naturally. Breckwell says to check the heater for smoke spilling into the room and open a window if any does. When power returns, Breckwell's stove may resume feeding fuel if it is still warm, while Castle's will not restart on its own.

Pellet stoves and backup power

That outage behavior is why pellet stoves come up so often in backup planning. Once lit, a stove drawing about 200 W is a modest load. As a rough guide, 10 kWh of usable battery capacity could run it for about 50 hours on its own — before inverter losses and before anything else on the backed-up circuits. In practice it shares the battery with refrigeration, a sump pump, lights and internet, so the planning question is what else stays on.

Our critical load panel planner helps you sort that list, and how many watts a furnace uses covers the gas-furnace blower, the other heating load that stops without power. Outage history varies a lot by utility — see, for example, battery backup in Rochester after the 2017 windstorm or in Allentown after PPL's July 2026 storms.

If you're planning home battery backup and want your pellet stove on it, Seamless Home coordinates the design and installation — get a free estimate to start. Coverage is confirmed per service area rather than promised as blanket availability.

Frequently asked questions

How many watts does a pellet stove use while running?

The two manuals cited here list about 175 W (Breckwell SP8000) and 200 W (Castle HPS09) while operating. That power runs the auger motor, combustion exhaust fan, room blower and control board. Your own stove's manual or rating label lists its figure.

How many watts does a pellet stove use when it starts?

More, because the electric igniter heats the pellets. Breckwell lists about 425 W with the igniter running and Castle lists 520 W during ignition. Breckwell says the fuel should ignite within 5 to 10 minutes of pressing ON.

How many amps does a pellet stove draw?

The manuals list the electrical rating at 110–120 volts, 60 Hz: 3.0 amps for the Breckwell SP8000 and 4.5 amps for the Castle HPS09. That fits comfortably on a standard household circuit, though both manufacturers call for a grounded outlet and a surge protector.

How much electricity does a pellet stove use per day?

Multiply operating watts by hours and divide by 1,000. A stove drawing 200 W for 24 hours uses 4.8 kWh; at 175 W it is 4.2 kWh. Each startup adds a little: 520 W for 10 minutes is under 0.1 kWh.

Does a pellet stove work during a power outage?

No. Breckwell's manual says the heater will not operate during a power outage, and Castle's says the stove shuts down safely and the exhaust fan stops. Castle also warns the stove should not be the only heat source in the house, because outages cause a total loss of heat.

Can a home battery run a pellet stove?

Yes, a pellet stove is a modest load for a home battery once it is running. As a rough guide, 10 kWh of usable storage could run a 200 W stove for about 50 hours on its own, before inverter losses and anything else on the backed-up circuits. The igniter's startup draw needs to fit within the inverter's capacity too.

What should I do when the power goes out with the stove on?

Follow your manual. Castle says to keep the main and ash doors closed so the vent can draft naturally, and Breckwell says to check for smoke spilling into the room and open a window if it does. Breckwell's stove may resume if still warm; Castle's will not restart on its own.

Ready to close more deals and hand off the rest?

Seamless Home connects your organization to financing, discounted materials, vetted installers, and full project management, so you can focus on selling.

Get In Touch